Electric Tankless Water Heater Sizes and Their Wiring Needs
An electric tankless heater warms water with elements that only switch on when a tap opens. There's no burner and no flue, which makes it the natural fit for a Port St. Lucie house that has never had gas. What separates one install from the next is the heater's size in kilowatts and what that size asks of the panel.

Large 27-36 kW Whole-House Electric Units
These are the models that replace a 40- or 50-gallon tank for a family. Angi's guide puts 27 to 36 kW units in the "expansive home" bracket. The warm inlet water here stretches them further than their northern ratings suggest (sizing for warm inlet water).
- EcoSmart ECO 27: 27 kW from three 9 kW elements, 112.5 amps, 5.2 GPM with 70°F inlet water
- Stiebel Eltron Tempra 29: 28.8 kW, raises 3 GPM by 66°F
- Stiebel Eltron Tempra 36: 36 kW, raises 3 GPM by 82°F, more than this climate usually needs

Smaller Electric Units for One-Bath Homes and Condos
A one-bath villa or a condo with a single shower rarely needs the biggest model. Angi sizes 10 to 24 kW units for two-bedroom homes. A smaller unit draws fewer amps and may fit a panel that a 27 kW unit would overload. For a single sink or a pool bath far from the main heater, a point-of-use unit is the cheaper route.
- EcoSmart ECO 18: 75 amps on two 40-amp breakers, 3.5 GPM with 70°F water
- Stiebel Eltron Tempra 24: 24 kW on two 50-amp breakers, recommended 150-amp main service

Breakers, Wire Gauge and the 200-Amp Service Question
Most quotes rise or fall on this section. Stiebel Eltron's spec sheet sets a minimum main service for each model: 150 amps for the Tempra 24, 200 for the Tempra 29 and 300 for the Tempra 36. Rinnai's FAQ makes the same point from the other side: 3 gallons a minute with an 80°F rise needs about a 150-amp, 230-volt circuit. A house on 150-amp service with central air, an electric range and a pool pump may need a service upgrade before anything else.
- Wire: three sets of 8 AWG for the ECO 27, three runs of 8/2 for the Tempra 29 and 36
- New dedicated circuit: $250 to $900 (HomeGuide) or $200 to $600 (This Old House)
- Panel replacement: $850 to $1,700 (HomeGuide); a full upgrade $1,000 to $2,000 (This Old House)

Mounting an Electric Unit Where the Old Tank Stood
The old tank's water lines are usually right there, so the heater often goes on the same wall. Because there's no combustion, no vent pipe is needed. Florida's plumbing code still governs the spot: a disconnecting means for the power, its own shutoff valve on the cold line, and a level working space of at least 30 by 30 inches in front of the controls. The freed floor space is a bonus in a one-car garage.

Why Port St. Lucie homeowners and businesses call Port St. Lucie Tankless Water Heater
- Sending a request is free and doesn't commit you to anything
- Your details go to one licensed plumber, never a list of callers
- Ask for the unit's flow rate at your water temperature in writing
- Ask who files the city permit and books the inspection
- The referral adds nothing to the plumber's price
Electric Tankless Cost in Port St. Lucie: Unit, Labor and Panel
HomeGuide's installed range for electric tankless runs $1,400 to $3,000, and This Old House puts the whole job at $650 to $2,500. Neither includes a service upgrade. The heater is the easy part to price; a panel replacement alone can add $850 to $2,000. This Old House lists plumber rates of $75 to $150 an hour over a 4- to 8-hour job, and the electrician bills separately on top of that, so ask to see both labor lines.
Running costs are lower than a tank's. HomeGuide estimates $340 to $540 a year for electric tankless and $530 to $600 for an electric tank. FPL's September 2026 residential rate works out to roughly 11.5 cents per kWh for the first 1,000 kWh before taxes, our own sum of its posted charges. One trade-off for anyone on FPL's On Call program: tankless heaters are excluded from its water heater credit (water heater replacement covers that choice).
What to Check Before the Electrician Looks at the Panel
The site visit goes faster when the answers are ready. Collect these before the call:
Main breaker size
The amp number printed on the main breaker handle.Open slots
Each double-pole breaker takes two spaces, so a three-breaker unit needs six.Big loads already on the panel
Central air, an electric range, a dryer, a pool pump or an EV charger.Distance
How far the heater spot is from the panel, since heavy-gauge wire is priced by the foot.Permit split
The city lists separate electrical permits; ask whether the quote covers both the permit and plan review and the electrical side.
If the panel can't carry a whole-house unit, compare a heat pump water heater or a natural gas tankless unit where a Florida City Gas main reaches the street.